PROBLEM
To find a fast, efficient method for total removal of flash on molded plastic parts.
SOLUTION
Use high pressure water in a specially designed automated system.
SPECIFICATIONS
Pump Model (three)........................................................KB 32
Pressure.............................245 Kg/cm2 / 240 bar / 3490 psi
Flow (each)..............….........................90 lpm / 23.7 US gpm
Temperature ....................................................................125°F
Fluid...................................................................................Water
Duty Cycle ..............................................................Continuous
Drive (three).........................................................60 hp Electric
BENEFITS
- Removes flash at a rate of 1.25 seconds per part.
- Only requires one person, operating 2 systems to deflash 5760 parts per hour.
- Significantly reduces lead time for parts.
- Dependable, continuous duty this high pressure pump assures system “up time” and minimizes maintenance “downtime”.